SIC
close
Image Product Number Pricing(USD) Quantity ECAD Quantity Available Weight(Kg) Mfr Series Package Product Status Operating Temperature Applications Size / Dimension Mounting Type Type Features Base Product Number Approval Agency Voltage - Input DataSheet RoHS Status Moisture Sensitivity Level (MSL) REACH Status Other Names ECCN HTSUS Standard Package Power (Watts) Number of Outputs Efficiency Voltage - Output 1 Voltage - Output 2 Voltage - Output 3 Voltage - Output 4 Voltage - Output 5 Voltage - Output 6 Minimum Load Required Voltage - Isolation Standard Number Current - Output 1 Current - Output 2 Current - Output 3 Current - Output 4 Current - Output 5 Current - Output 6
CX10S-BAABHA-P-A-DK00000 Advanced Energy CX10S-BAABHA-P-A-DK00000 -
RFQ
ECAD 6630 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-BAABHA-P-A-DK00000 EAR99 8504.40.9540 1 775W 7 93% 12V 5V 5V 12V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 15 A 21 A 21 A 15 A 6 A 3 A
CX10S-DBDDAB-P-A-DK00000 Advanced Energy CX10S-DBDDAB-P-A-DK00000 -
RFQ
ECAD 5545 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DBDDAB-P-A-DK00000 EAR99 8504.40.9540 1 1000W 6 93% 48V 12V 48V 48V 5V 12V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 15 A 4.17 A 4.17 A 21 A 15 A
CX10S-BBHCCC-P-A-DK00000 Advanced Energy CX10S-BBHCCC-P-A-DK00000 -
RFQ
ECAD 9956 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-BBHCCC-P-A-DK00000 EAR99 8504.40.9540 1 1000W 7 93% 12V 12V 5V 24V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 15 A 15 A 6 A 3 A 8.3 A 8.3 A
CX10S-A0B0DB-P-A-DK00000 Advanced Energy CX10S-A0B0DB-P-A-DK00000 -
RFQ
ECAD 2831 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-A0B0DB-P-A-DK00000 EAR99 8504.40.9540 1 665W 4 93% 5V 12V 48V 12V - - No 4 kV 60601-1; 60950-1; 62368-1 21 A 15 A 4.17 A 15 A
NMP1K2-EC#CEK-00 MEAN WELL USA Inc. NMP1K2-EC#CEK-00 728.6700
RFQ
ECAD 3561 0.00000000 MEAN WELL USA Inc. NMP (1200W) Box Active -30°C ~ 70°C (With Derating) ITE (Commercial), Medical 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) Chassis Mount Enclosed Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input NMP1K2 CB, CE, cURus, EAC, TUV 90 ~ 264 VAC, 120 ~ 370 VDC download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9540 1 1080W 5 88.5% 12V 5V 5V 12V 48V - - 4 kV 60601-1; 62368-1 20 A 36 A 36 A 20 A 5 A
CX10S-CDAD0B-P-A-DK00000 Advanced Energy CX10S-CDAD0B-P-A-DK00000 -
RFQ
ECAD 3143 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-CDAD0B-P-A-DK00000 EAR99 8504.40.9540 1 885W 5 93% 24V 48V 5V 48V 12V 24V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 4.17 A 21 A 4.17 A 15 A
LDC15F-1-SNY Cosel USA, Inc. LDC15F-1-SNY 63.7400
RFQ
ECAD 9916 0.00000000 Cosel USA, Inc. LDC (15W) Box Last Time Buy -10°C ~ 60°C (With Derating) ITE (Commercial) 1.97" L x 1.02" W x 5.00" H (50.0mm x 25.9mm x 127.0mm) Chassis Mount Enclosed Adjustable Output, Universal Input LDC15F CE, CSA, cURus, TUV 85 ~ 264 VAC, 110 ~ 370 VDC download ROHS3 Compliant Not Applicable EAR99 8504.40.9510 1 10W 3 72% 5V 12V -12V - - - - 3 kV 60950-1 2 A 300 mA 200 mA
CX10S-BDC0DH-P-A-DK00000 Advanced Energy CX10S-BDC0DH-P-A-DK00000 -
RFQ
ECAD 7755 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-BDC0DH-P-A-DK00000 EAR99 8504.40.9540 1 880W 6 93% 12V 48V 24V 48V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 15 A 4.17 A 8.3 A 4.17 A 6 A 3 A
CX10S-B0AB0H-P-A-DK00000 Advanced Energy CX10S-B0AB0H-P-A-DK00000 -
RFQ
ECAD 8714 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-B0AB0H-P-A-DK00000 EAR99 8504.40.9540 1 565W 5 93% 12V 5V 12V 5V 24V 12V No 4 kV 60601-1; 60950-1; 62368-1 15 A 21 A 15 A 6 A 3 A
CX10S-DACGCA-P-A-DK00000 Advanced Energy CX10S-DACGCA-P-A-DK00000 -
RFQ
ECAD 1047 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DACGCA-P-A-DK00000 EAR99 8504.40.9540 1 930W 7 93% 48V 5V 24V 24V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 21 A 8.3 A 3 A 3 A 8.3 A
CX10S-HHCABC-P-A-DK00000 Advanced Energy CX10S-HHCABC-P-A-DK00000 -
RFQ
ECAD 9581 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-HHCABC-P-A-DK00000 EAR99 8504.40.9540 1 885W 8 93% 5V 24V 5V 24V 24V 5V No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 6 A 3 A 8.3 A 21 A
CX10S-GAHHCA-P-A-DK00000 Advanced Energy CX10S-GAHHCA-P-A-DK00000 -
RFQ
ECAD 8604 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GAHHCA-P-A-DK00000 EAR99 8504.40.9540 1 730W 9 93% 24V 24V 5V 5V 24V 5V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 21 A 6 A 3 A 6 A
CX10S-CGBG0H-P-A-DK00000 Advanced Energy CX10S-CGBG0H-P-A-DK00000 -
RFQ
ECAD 1550 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-CGBG0H-P-A-DK00000 EAR99 8504.40.9540 1 720W 8 93% 24V 24V 24V 12V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 3 A 3 A 15 A 3 A 3 A
VP-F2357818 Vicor Corporation VP-F2357818 -
RFQ
ECAD 9772 0.00000000 Vicor Corporation * Bulk Obsolete VP-F - 1 (Unlimited) REACH Affected OBSOLETE 1
CX10S-GBGHDC-P-A-DK00000 Advanced Energy CX10S-GBGHDC-P-A-DK00000 -
RFQ
ECAD 7085 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GBGHDC-P-A-DK00000 EAR99 8504.40.9540 1 920W 9 93% 24V 24V 12V 24V 24V 5V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 15 A 3 A 3 A 6 A
CX10S-GAAGBD-P-A-DK00000 Advanced Energy CX10S-GAAGBD-P-A-DK00000 -
RFQ
ECAD 1989 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GAAGBD-P-A-DK00000 EAR99 8504.40.9540 1 830W 8 93% 24V 24V 5V 5V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 21 A 21 A 3 A 3 A
CX10S-GGDAAD-P-A-DK00000 Advanced Energy CX10S-GGDAAD-P-A-DK00000 -
RFQ
ECAD 8544 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GGDAAD-P-A-DK00000 EAR99 8504.40.9540 1 850W 8 93% 24V 24V 24V 24V 48V 5V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 3 A 3 A 4.17 A 21 A
CX10S-DGGCBH-P-A-DK00000 Advanced Energy CX10S-DGGCBH-P-A-DK00000 -
RFQ
ECAD 7048 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DGGCBH-P-A-DK00000 EAR99 8504.40.9540 1 920W 9 93% 48V 24V 24V 24V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 3 A 3 A 3 A 3 A 8.3 A
CX10S-00BADA-P-A-DK00000 Advanced Energy CX10S-00BADA-P-A-DK00000 -
RFQ
ECAD 9270 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-00BADA-P-A-DK00000 EAR99 8504.40.9540 1 590W 4 93% 12V 5V 48V 5V - - No 4 kV 60601-1; 60950-1; 62368-1 15 A 21 A 4.17 A 21 A
NFS40-7910J Artesyn Embedded Power NFS40-7910J -
RFQ
ECAD 6309 0.00000000 Artesyn Embedded Power NFS40 (40W) Bulk Obsolete 0°C ~ 70°C (With Derating) Medical 5.00" L x 3.00" W x 1.20" H (127.0mm x 76.2mm x 30.5mm) Chassis Mount Open Frame Adjustable Output, DC Input Capable, Universal Input - 85 ~ 264 VAC download 1 (Unlimited) EAR99 8504.40.6007 1 40W (50W Forced Air) 3 70% 5.1V 15V -15V - - Yes 4 kV 3 A 2 A 350 mA
DZ065V-19 Tri-Mag, LLC DZ065V-19 64.7360
RFQ
ECAD 7775 0.00000000 Tri-Mag, LLC Tri-Mag, DZ065V (65W) Box Active 0°C ~ 70°C (With Derating) ITE (Commercial) 4.00" L x 2.00" W x 1.20" H (101.6mm x 50.8mm x 28.0mm) Chassis Mount Open Frame Universal Input DZ065 - 90 ~ 264 VAC download ROHS3 Compliant 1 (Unlimited) EAR99 8504.40.6018 1 65W 3 85% 3.3V 5V 12V - - No 5 A 3 A 700 mA
IMP1-3W0-2Q0-2Q0-00 Artesyn Embedded Power IMP1-3W0-2Q0-2Q0-00 -
RFQ
ECAD 4795 0.00000000 Artesyn Embedded Power iMP® (1500W) Bulk Active -40°C ~ 70°C (With Derating) ITE (Commercial), Medical 11.00" L x 8.00" W x 2.50" H (279.4mm x 203.2mm x 63.5mm) Chassis Mount Enclosed Adjustable Output, I²C Interface, PFC, PMBus™, Remote Sense, Universal Input IMP1-3W0 CB, CE, CSA, UL 85 ~ 264 VAC, 120 ~ 300 VDC - RoHS Compliant Not Applicable EAR99 8504.40.9540 1 1469W 3 85% 48V 24V 24V - - - No 2 kV 15.6 A 15 A 15 A
CX10S-BDBDB0-P-A-DK00000 Advanced Energy CX10S-BDBDB0-P-A-DK00000 -
RFQ
ECAD 8545 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-BDBDB0-P-A-DK00000 EAR99 8504.40.9540 1 940W 5 93% 12V 48V 12V 48V 12V 12V No 4 kV 60601-1; 60950-1; 62368-1 15 A 4.17 A 15 A 4.17 A 15 A
NMP1K2-CEKKK#-04 MEAN WELL USA Inc. NMP1K2-CEKKK#-04 733.5900
RFQ
ECAD 1893 0.00000000 MEAN WELL USA Inc. NMP (1200W) Box Active -30°C ~ 70°C (With Derating) ITE (Commercial), Medical 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) Chassis Mount Enclosed Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input NMP1K2 CB, CE, cURus, EAC, TUV 90 ~ 264 VAC, 120 ~ 370 VDC download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9540 1 1140W 4 88.5% 5V 12V 48V 48V - - 4 kV 60601-1; 62368-1 36 A 20 A 5 A 10 A
CX10S-000GAC-P-A-DK00000 Advanced Energy CX10S-000GAC-P-A-DK00000 -
RFQ
ECAD 9196 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-000GAC-P-A-DK00000 EAR99 8504.40.9540 1 425W 4 93% 24V 24V 5V 24V - - No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 21 A 8.3 A
NMP1K2-CKEEEH-04 MEAN WELL USA Inc. NMP1K2-CKEEEH-04 821.0300
RFQ
ECAD 8541 0.00000000 MEAN WELL USA Inc. NMP (1200W) Box Active -30°C ~ 70°C (With Derating) ITE (Commercial), Medical 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) Chassis Mount Enclosed Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input NMP1K2 CB, CE, cURus, EAC, TUV 90 ~ 264 VAC, 120 ~ 370 VDC download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9540 1 1200W 5 88.5% 5V 48V 12V 12V 12V 24V - 4 kV 60601-1; 62368-1 36 A 5 A 20 A 20 A 20 A 10 A
CX10S-HBDHAC-P-A-DK00000 Advanced Energy CX10S-HBDHAC-P-A-DK00000 -
RFQ
ECAD 8337 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-HBDHAC-P-A-DK00000 EAR99 8504.40.9540 1 885W 8 93% 5V 24V 12V 48V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 15 A 4.17 A 6 A 3 A
W30FT400 Acopian Power Supplies W30FT400 377.0000
RFQ
ECAD 500 0.00000000 Acopian Power Supplies - Bulk Active 0°C ~ 71°C Industrial, ITE (Commercial) 6.59" L x 3.45" W x 1.68" H (167.4mm x 87.6mm x 42.7mm) Chassis Mount Enclosed DC Input Capable, Remote Sense CE, cULus, cURus 90 ~ 132 VAC, 200 ~ 375 VDC download RoHS Compliant Not Applicable 5006-W30FT400 EAR99 8504.40.9550 1 120W 1 80% 30V - - - - - No 4.242 kV 60950-1; UL 508 4 A 4 A 4 A 4 A 4 A 4 A
NTS508-CF Artesyn Embedded Power NTS508-CF -
RFQ
ECAD 8102 0.00000000 Artesyn Embedded Power NTS500 (500W) Bulk Obsolete 0°C ~ 70°C (With Derating) ITE (Commercial) 7.00" L x 4.00" W x 1.50" H (177.8mm x 101.6mm x 38.1mm) Chassis Mount Open Frame Adjustable Output, I²C™ Interface, Load Sharing, PFC, PMBus™, Remote On/Off, Remote Sense, Standby Output, Universal Input CB, CE 85 ~ 264 VAC download 1 (Unlimited) EAR99 8504.40.6018 36 200W (500W Forced Air) 1 85% 48V - - - - - 4.2 A
CX10S-00ADDC-P-A-DK00000 Advanced Energy CX10S-00ADDC-P-A-DK00000 -
RFQ
ECAD 8288 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-00ADDC-P-A-DK00000 EAR99 8504.40.9540 1 705W 4 93% 5V 48V 48V 24V - - No 4 kV 60601-1; 60950-1; 62368-1 21 A 4.17 A 4.17 A 8.3 A
  • Daily average RFQ Volume

    2000+

    Daily average RFQ Volume

  • Standard Product Unit

    30,000,000

    Standard Product Unit

  • Worldwide Manufacturers

    2800+

    Worldwide Manufacturers

  • In-stock Warehouse

    15,000 m2

    In-stock Warehouse