SIC
close
Image Product Number Pricing(USD) Quantity ECAD Quantity Available Weight(Kg) Mfr Series Package Product Status Operating Temperature Applications Size / Dimension Mounting Type Type Features Base Product Number Approval Agency Voltage - Input DataSheet RoHS Status Moisture Sensitivity Level (MSL) REACH Status Other Names ECCN HTSUS Standard Package Power (Watts) Number of Outputs Efficiency Voltage - Output 1 Voltage - Output 2 Voltage - Output 3 Voltage - Output 4 Voltage - Output 5 Voltage - Output 6 Minimum Load Required Voltage - Isolation Standard Number Current - Output 1 Current - Output 2 Current - Output 3 Current - Output 4 Current - Output 5 Current - Output 6
NMP1K2-CC#C##-01 MEAN WELL USA Inc. NMP1K2-CC#C##-01 558.7000
RFQ
ECAD 1922 0.00000000 MEAN WELL USA Inc. NMP (1200W) Box Active -30°C ~ 70°C (With Derating) ITE (Commercial), Medical 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) Chassis Mount Enclosed Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input NMP1K2 CB, CE, cURus, EAC, TUV 90 ~ 264 VAC, 120 ~ 370 VDC download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9540 1 540W 2 88.5% 5V 5V - - - - 4 kV 60601-1; 62368-1 72 A 36 A
CX10S-CGHB0D-P-A-DK00000 Advanced Energy CX10S-CGHB0D-P-A-DK00000 -
RFQ
ECAD 2859 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-CGHB0D-P-A-DK00000 EAR99 8504.40.9540 1 800W 7 93% 24V 24V 24V 5V 24V 12V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 3 A 3 A 6 A 3 A 15 A
CX10S-00BHGG-P-A-DK00000 Advanced Energy CX10S-00BHGG-P-A-DK00000 -
RFQ
ECAD 1922 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-00BHGG-P-A-DK00000 EAR99 8504.40.9540 1 520W 7 93% 12V 5V 24V 24V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 15 A 6 A 3 A 3 A 3 A 3 A
CX10S-GADBBG-P-A-DK00000 Advanced Energy CX10S-GADBBG-P-A-DK00000 -
RFQ
ECAD 2738 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GADBBG-P-A-DK00000 EAR99 8504.40.9540 1 905W 8 93% 24V 24V 5V 48V 12V 12V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 21 A 4.17 A 15 A 15 A
CX10S-C0ADB0-P-A-DK00000 Advanced Energy CX10S-C0ADB0-P-A-DK00000 -
RFQ
ECAD 7216 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-C0ADB0-P-A-DK00000 EAR99 8504.40.9540 1 685W 4 93% 24V 5V 48V 12V - - No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 21 A 4.17 A 15 A
LHA30F-12 Cosel USA, Inc. LHA30F-12 29.6700
RFQ
ECAD 3024 0.00000000 Cosel USA, Inc. LHA (30W) Box Active -10°C ~ 70°C ITE (Commercial) 3.44" L x 1.97" W x 0.93" H (87.4mm x 50.0mm x 23.6mm) Chassis Mount Open Frame Adjustable Output, Universal Input LHA30F CE, cURus, DEMKO, UL 85 ~ 264 VAC download ROHS3 Compliant Not Applicable 1776-LHA30F-12 EAR99 8504.40.9510 1 30W 1 88.5% 12V - - - - - - 3 kV 62368-1 2.5 A
CX10S-GD0DD0-P-A-DK00000 Advanced Energy CX10S-GD0DD0-P-A-DK00000 -
RFQ
ECAD 4543 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GD0DD0-P-A-DK00000 EAR99 8504.40.9540 1 720W 5 93% 24V 24V 48V 48V 48V 24V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 4.17 A 4.17 A 4.17 A
CX10S-AB0H0G-P-A-DK00000 Advanced Energy CX10S-AB0H0G-P-A-DK00000 -
RFQ
ECAD 2990 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-AB0H0G-P-A-DK00000 EAR99 8504.40.9540 1 505W 6 93% 5V 12V 5V 24V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 21 A 15 A 6 A 3 A 3 A 3 A
CX10S-A000AA-P-A-DK00000 Advanced Energy CX10S-A000AA-P-A-DK00000 -
RFQ
ECAD 3276 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-A000AA-P-A-DK00000 EAR99 8504.40.9540 1 315W 3 93% 5V 5V 5V - - - No 4 kV 60601-1; 60950-1; 62368-1 21 A 21 A 21 A
CX10S-GD0DDD-P-A-DK00000 Advanced Energy CX10S-GD0DDD-P-A-DK00000 -
RFQ
ECAD 5760 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GD0DDD-P-A-DK00000 EAR99 8504.40.9540 1 920W 6 93% 24V 24V 48V 48V 48V 48V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 4.17 A 4.17 A 4.17 A 4.17 A
CX10S-AA0CB0-P-A-DK00000 Advanced Energy CX10S-AA0CB0-P-A-DK00000 -
RFQ
ECAD 4354 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-AA0CB0-P-A-DK00000 EAR99 8504.40.9540 1 590W 4 93% 5V 5V 24V 12V - - No 4 kV 60601-1; 60950-1; 62368-1 21 A 21 A 8.3 A 15 A
NEVO+600S-5085-DK000 Vox Power Ltd. NEVO+600S-5085-DK000 381.3560
RFQ
ECAD 8877 0.00000000 Vox Power Ltd. NEVO+600S Box Active -20°C ~ 70°C ITE (Commercial) 3.06" L x 3.06" W x 1.61" H (77.7mm x 77.7mm x 41.0mm) Chassis Mount Enclosed Adjustable Output, Load Sharing, PFC, Remote Sense, Universal Input NEVO+600 CB, CE, CSA, IEC, UL 85 ~ 264 VAC, 120 ~ 370 VDC download Not Applicable REACH Unaffected 2050-NEVO+600S-5085-DK000 EAR99 8504.40.9540 1 300W 4 86% 12V 12V 24V 24V 12V 12V No 4 kV 60950-1; 62368-1 5 A 5 A 3.125 A 3.125 A 5 A 5 A
CX10S-CHCGHH-P-A-DK00000 Advanced Energy CX10S-CHCGHH-P-A-DK00000 -
RFQ
ECAD 4544 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-CHCGHH-P-A-DK00000 EAR99 8504.40.9540 1 820W 10 93% 24V 5V 24V 24V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 6 A 3 A 8.3 A 3 A 3 A
NMP1K2-K#KK#E-03 MEAN WELL USA Inc. NMP1K2-K#KK#E-03 646.1400
RFQ
ECAD 7173 0.00000000 MEAN WELL USA Inc. NMP (1200W) Box Active -30°C ~ 70°C (With Derating) ITE (Commercial), Medical 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) Chassis Mount Enclosed Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input NMP1K2 CB, CE, cURus, EAC, TUV 90 ~ 264 VAC, 120 ~ 370 VDC download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9540 1 960W 3 88.5% 48V 48V 12V - - - 4 kV 60601-1; 62368-1 5 A 10 A 20 A
CX10S-DHA0HG-P-A-DK00000 Advanced Energy CX10S-DHA0HG-P-A-DK00000 -
RFQ
ECAD 5203 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DHA0HG-P-A-DK00000 EAR99 8504.40.9540 1 625W 8 93% 48V 5V 24V 5V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 6 A 3 A 21 A 6 A 3 A
CX10S-B0GGDB-P-A-DK00000 Advanced Energy CX10S-B0GGDB-P-A-DK00000 -
RFQ
ECAD 5292 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-B0GGDB-P-A-DK00000 EAR99 8504.40.9540 1 800W 7 93% 12V 24V 24V 24V 24V 48V No 4 kV 60601-1; 60950-1; 62368-1 15 A 3 A 3 A 3 A 3 A 4.17 A
CX10S-CBDBBG-P-A-DK00000 Advanced Energy CX10S-CBDBBG-P-A-DK00000 -
RFQ
ECAD 3967 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-CBDBBG-P-A-DK00000 EAR99 8504.40.9540 1 1000W 7 93% 24V 12V 48V 12V 12V 24V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 15 A 4.17 A 15 A 15 A 3 A
CX10S-H00A00-P-A-DK00000 Advanced Energy CX10S-H00A00-P-A-DK00000 -
RFQ
ECAD 5911 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-H00A00-P-A-DK00000 EAR99 8504.40.9540 1 205W 3 93% 5V 24V 5V - - - No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 21 A
CX10S-0ADH0A-P-A-DK00000 Advanced Energy CX10S-0ADH0A-P-A-DK00000 -
RFQ
ECAD 9591 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-0ADH0A-P-A-DK00000 EAR99 8504.40.9540 1 510W 5 93% 5V 48V 5V 24V 5V 5V No 4 kV 60601-1; 60950-1; 62368-1 21 A 4.17 A 6 A 3 A 21 A
CX10S-HAAGDA-P-A-DK00000 Advanced Energy CX10S-HAAGDA-P-A-DK00000 -
RFQ
ECAD 4139 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-HAAGDA-P-A-DK00000 EAR99 8504.40.9540 1 735W 8 93% 5V 24V 5V 5V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 21 A 21 A 3 A 3 A
CX10S-CGG0GH-P-A-DK00000 Advanced Energy CX10S-CGG0GH-P-A-DK00000 -
RFQ
ECAD 3314 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-CGG0GH-P-A-DK00000 EAR99 8504.40.9540 1 660W 9 93% 24V 24V 24V 24V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 3 A 3 A 3 A 3 A 3 A
NMP1K2-CHK##C-00 MEAN WELL USA Inc. NMP1K2-CHK##C-00 641.2200
RFQ
ECAD 1657 0.00000000 MEAN WELL USA Inc. NMP (1200W) Box Active -30°C ~ 70°C (With Derating) ITE (Commercial), Medical 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) Chassis Mount Enclosed Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input NMP1K2 CB, CE, cURus, EAC, TUV 90 ~ 264 VAC, 120 ~ 370 VDC download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9540 1 840W 4 88.5% 5V 24V 48V 5V - - 4 kV 60601-1; 62368-1 36 A 10 A 5 A 36 A
FL3-30-10368 Vicor Corporation FL3-30-10368 -
RFQ
ECAD 4998 0.00000000 Vicor Corporation * Bulk Obsolete - Not Applicable 1102-FL3-30-10368 OBSOLETE 1
CX10S-HBGBBG-P-A-DK00000 Advanced Energy CX10S-HBGBBG-P-A-DK00000 -
RFQ
ECAD 2132 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-HBGBBG-P-A-DK00000 EAR99 8504.40.9540 1 880W 9 93% 5V 24V 12V 24V 24V 12V No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 15 A 3 A 3 A 15 A
FLS250-1015 Bel Power Solutions FLS250-1015 208.6154
RFQ
ECAD 3241 0.00000000 Bel Power Solutions FLS250 (250W) Box Active -40°C ~ 70°C (With Derating) ITE (Commercial) 4.50" L x 2.50" W x 1.57" H (114.3mm x 63.5mm x 39.9mm) Chassis Mount Open Frame Adjustable Output, DC Input Capable, PFC, Universal Input CB, CE, CSA, NEMKO, UL 85 ~ 264 VAC, 120 ~ 370 VDC download ROHS3 Compliant Not Applicable REACH Unaffected 179-FLS250-1015 EAR99 8504.40.9530 24 200W (300W Forced Air) 1 94% 15V - - - - - - 4 kV 62368-1 20 A
CX10S-GA0HDG-P-A-DK00000 Advanced Energy CX10S-GA0HDG-P-A-DK00000 -
RFQ
ECAD 6044 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GA0HDG-P-A-DK00000 EAR99 8504.40.9540 1 645W 8 93% 24V 24V 5V 5V 24V 48V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 21 A 6 A 3 A 4.17 A
CX10S-GAGGAC-P-A-DK00000 Advanced Energy CX10S-GAGGAC-P-A-DK00000 -
RFQ
ECAD 8401 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GAGGAC-P-A-DK00000 EAR99 8504.40.9540 1 770W 9 93% 24V 24V 5V 24V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 21 A 3 A 3 A 3 A
CX10S-CBGCHC-P-A-DK00000 Advanced Energy CX10S-CBGCHC-P-A-DK00000 -
RFQ
ECAD 1611 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-CBGCHC-P-A-DK00000 EAR99 8504.40.9540 1 1000W 8 93% 24V 12V 24V 24V 24V 5V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 15 A 3 A 3 A 8.3 A 6 A
VCCM600M-BBA0-DK000 Vox Power Ltd. VCCM600M-BBA0-DK000 460.9660
RFQ
ECAD 8634 0.00000000 Vox Power Ltd. VCCM600M Box Active -40°C ~ 70°C Medical 7.00" L x 4.00" W x 1.57" H (177.8mm x 101.6mm x 40.0mm) Chassis Mount Open Frame Adjustable Output, Load Sharing, PFC, Remote Sense, Universal Input VCCM600 CB, CE, CSA, UL 85 ~ 264 VAC, 120 ~ 370 VDC download Not Applicable REACH Unaffected 2050-VCCM600M-BBA0-DK000 EAR99 8504.40.9540 1 425W 3 90% 12V 12V 5V - - - No 4 kV 60601-1 15 A 15 A 25 A
CX10S-0A0DGD-P-A-DK00000 Advanced Energy CX10S-0A0DGD-P-A-DK00000 -
RFQ
ECAD 8235 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-0A0DGD-P-A-DK00000 EAR99 8504.40.9540 1 625W 5 93% 5V 48V 24V 24V 48V 5V No 4 kV 60601-1; 60950-1; 62368-1 21 A 4.17 A 3 A 3 A 4.17 A
  • Daily average RFQ Volume

    2000+

    Daily average RFQ Volume

  • Standard Product Unit

    30,000,000

    Standard Product Unit

  • Worldwide Manufacturers

    2800+

    Worldwide Manufacturers

  • In-stock Warehouse

    15,000 m2

    In-stock Warehouse