SIC
close
Image Product Number Pricing(USD) Quantity ECAD Quantity Available Weight(Kg) Mfr Series Package Product Status Operating Temperature Applications Size / Dimension Mounting Type Type Features Base Product Number Approval Agency Voltage - Input DataSheet RoHS Status Moisture Sensitivity Level (MSL) REACH Status Other Names ECCN HTSUS Standard Package Power (Watts) Number of Outputs Efficiency Voltage - Output 1 Voltage - Output 2 Voltage - Output 3 Voltage - Output 4 Voltage - Output 5 Voltage - Output 6 Minimum Load Required Voltage - Isolation Standard Number Current - Output 1 Current - Output 2 Current - Output 3 Current - Output 4 Current - Output 5 Current - Output 6
NMP1K2-HCKEKC-00 MEAN WELL USA Inc. NMP1K2-HCKEKC-00 816.1200
RFQ
ECAD 1453 0.00000000 MEAN WELL USA Inc. NMP (1200W) Box Active -30°C ~ 70°C (With Derating) ITE (Commercial), Medical 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) Chassis Mount Enclosed Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input NMP1K2 CB, CE, cURus, EAC, TUV 90 ~ 264 VAC, 120 ~ 370 VDC download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9540 1 1200W 6 88.5% 24V 5V 48V 12V 48V 5V - 4 kV 60601-1; 62368-1 10 A 36 A 5 A 20 A 5 A 36 A
CX10S-A0BGDA-P-A-DK00000 Advanced Energy CX10S-A0BGDA-P-A-DK00000 -
RFQ
ECAD 8979 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-A0BGDA-P-A-DK00000 EAR99 8504.40.9540 1 710W 6 93% 5V 12V 24V 24V 48V 5V No 4 kV 60601-1; 60950-1; 62368-1 21 A 15 A 3 A 3 A 4.17 A 21 A
CX10S-G0D0CG-P-A-DK00000 Advanced Energy CX10S-G0D0CG-P-A-DK00000 -
RFQ
ECAD 6672 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-G0D0CG-P-A-DK00000 EAR99 8504.40.9540 1 640W 6 93% 24V 24V 48V 24V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 4.17 A 8.3 A 3 A 3 A
IMP4-2L0-2W0-1W0-00-A Artesyn Embedded Power IMP4-2L0-2W0-1W0-00-A -
RFQ
ECAD 6489 0.00000000 Artesyn Embedded Power iMP® (1158W) Bulk Active -40°C ~ 70°C (With Derating) ITE (Commercial), Medical 10.00" L x 5.00" W x 2.50" H (254.0mm x 127.0mm x 63.5mm) Chassis Mount Enclosed Adjustable Output, I²C Interface, PFC, PMBus™, Remote Sense, Universal Input IMP4-2L0 CB, CE, CSA, UL 85 ~ 264 VAC, 120 ~ 300 VDC download RoHS Compliant 1 (Unlimited) EAR99 8504.40.9580 1 1100W 3 85% 12V 48V 48V - - - No 2 kV 30 A 7.5 A 4 A
NMP1K2-##EEEE-12 MEAN WELL USA Inc. NMP1K2-##EEEE-12 653.4300
RFQ
ECAD 5950 0.00000000 MEAN WELL USA Inc. NMP (1200W) Box Active -30°C ~ 70°C (With Derating) ITE (Commercial), Medical 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) Chassis Mount Enclosed Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input NMP1K2 CB, CE, cURus, EAC, TUV 90 ~ 264 VAC, 120 ~ 370 VDC download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9540 1 960W 1 88.5% 12V - - - - - 4 kV 60601-1; 62368-1 80 A
CX10S-CHAA00-P-A-DK00000 Advanced Energy CX10S-CHAA00-P-A-DK00000 -
RFQ
ECAD 2636 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-CHAA00-P-A-DK00000 EAR99 8504.40.9540 1 510W 5 93% 24V 5V 24V 5V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 6 A 3 A 21 A 21 A
CX10S-HBBHAD-P-A-DK00000 Advanced Energy CX10S-HBBHAD-P-A-DK00000 -
RFQ
ECAD 4651 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-HBBHAD-P-A-DK00000 EAR99 8504.40.9540 1 865W 8 93% 5V 24V 12V 12V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 15 A 15 A 6 A 3 A
CX10S-G0AGDG-P-A-DK00000 Advanced Energy CX10S-G0AGDG-P-A-DK00000 -
RFQ
ECAD 9093 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-G0AGDG-P-A-DK00000 EAR99 8504.40.9540 1 665W 8 93% 24V 24V 5V 24V 24V 48V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 21 A 3 A 3 A 4.17 A
CX10S-DHAADC-P-A-DK00000 Advanced Energy CX10S-DHAADC-P-A-DK00000 -
RFQ
ECAD 4986 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DHAADC-P-A-DK00000 EAR99 8504.40.9540 1 910W 7 93% 48V 5V 24V 5V 5V 48V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 6 A 3 A 21 A 21 A 4.17 A
CX10S-A0DACC-P-A-DK00000 Advanced Energy CX10S-A0DACC-P-A-DK00000 -
RFQ
ECAD 3812 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-A0DACC-P-A-DK00000 EAR99 8504.40.9540 1 810W 5 93% 5V 48V 5V 24V 24V 5V No 4 kV 60601-1; 60950-1; 62368-1 21 A 4.17 A 21 A 8.3 A 8.3 A
VI-QU31-IQU Vicor Corporation VI-QU31-IQU -
RFQ
ECAD 4023 0.00000000 Vicor Corporation * Bulk Obsolete VI-QU31 - RoHS non-compliant 1 (Unlimited) REACH Unaffected EAR99 8504.40.9540 1
CX10S-ACAGHC-P-A-DK00000 Advanced Energy CX10S-ACAGHC-P-A-DK00000 -
RFQ
ECAD 5046 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-ACAGHC-P-A-DK00000 EAR99 8504.40.9540 1 830W 8 93% 5V 24V 5V 24V 24V 5V No 4 kV 60601-1; 60950-1; 62368-1 21 A 8.3 A 21 A 3 A 3 A 6 A
NMP1K2-EKEHEE-00 MEAN WELL USA Inc. NMP1K2-EKEHEE-00 816.1200
RFQ
ECAD 4242 0.00000000 MEAN WELL USA Inc. NMP (1200W) Box Active -30°C ~ 70°C (With Derating) ITE (Commercial), Medical 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) Chassis Mount Enclosed Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input NMP1K2 CB, CE, cURus, EAC, TUV 90 ~ 264 VAC, 120 ~ 370 VDC download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9540 1 1200W 6 88.5% 12V 48V 12V 24V 12V 12V - 4 kV 60601-1; 62368-1 20 A 5 A 20 A 10 A 20 A 20 A
CX10S-DCBGGC-P-A-DK00000 Advanced Energy CX10S-DCBGGC-P-A-DK00000 -
RFQ
ECAD 4952 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DCBGGC-P-A-DK00000 EAR99 8504.40.9540 1 1000W 8 93% 48V 24V 12V 24V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 8.3 A 15 A 3 A 3 A 3 A
NMP1K2-CCHCCK-00 MEAN WELL USA Inc. NMP1K2-CCHCCK-00 777.6200
RFQ
ECAD 6964 0.00000000 MEAN WELL USA Inc. NMP (1200W) Box Active -30°C ~ 70°C (With Derating) ITE (Commercial), Medical 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) Chassis Mount Enclosed Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input NMP1K2 CB, CE, cURus, EAC, TUV 90 ~ 264 VAC, 120 ~ 370 VDC download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9540 1 1200W 6 88.5% 5V 5V 24V 5V 5V 48V - 4 kV 60601-1; 62368-1 36 A 36 A 10 A 36 A 36 A 5 A
VI-QU42-IQY Vicor Corporation VI-QU42-IQY -
RFQ
ECAD 3159 0.00000000 Vicor Corporation * Bulk Obsolete VI-QU42 - 1 (Unlimited) EAR99 8504.40.9530 1
VI-RU011-CYWY Vicor Corporation VI-RU011-CYWY -
RFQ
ECAD 8110 0.00000000 Vicor Corporation * Bulk Obsolete VI-RU011 - 1 (Unlimited) REACH Affected EAR99 8504.40.9510 1
CX10S-ACDHCD-P-A-DK00000 Advanced Energy CX10S-ACDHCD-P-A-DK00000 -
RFQ
ECAD 1201 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-ACDHCD-P-A-DK00000 EAR99 8504.40.9540 1 1000W 7 93% 5V 24V 48V 5V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 21 A 8.3 A 4.17 A 6 A 3 A 8.3 A
CX10S-0GG0GH-P-A-DK00000 Advanced Energy CX10S-0GG0GH-P-A-DK00000 -
RFQ
ECAD 9587 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-0GG0GH-P-A-DK00000 EAR99 8504.40.9540 1 460W 8 93% 24V 24V 24V 24V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 3 A 3 A 3 A 3 A
CX10S-0DGHBB-P-A-DK00000 Advanced Energy CX10S-0DGHBB-P-A-DK00000 -
RFQ
ECAD 6453 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-0DGHBB-P-A-DK00000 EAR99 8504.40.9540 1 780W 7 93% 48V 24V 24V 5V 24V 12V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 3 A 3 A 6 A 3 A 15 A
NMP1K2-##E#EE-00 MEAN WELL USA Inc. NMP1K2-##E#EE-00 553.7800
RFQ
ECAD 1080 0.00000000 MEAN WELL USA Inc. NMP (1200W) Box Active -30°C ~ 70°C (With Derating) ITE (Commercial), Medical 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) Chassis Mount Enclosed Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input NMP1K2 CB, CE, cURus, EAC, TUV 90 ~ 264 VAC, 120 ~ 370 VDC download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9540 1 720W 3 88.5% 12V 12V 12V - - - 4 kV 60601-1; 62368-1 20 A 20 A 20 A
NMP1K2-KCCE#C-00 MEAN WELL USA Inc. NMP1K2-KCCE#C-00 694.3000
RFQ
ECAD 9391 0.00000000 MEAN WELL USA Inc. NMP (1200W) Box Active -30°C ~ 70°C (With Derating) ITE (Commercial), Medical 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) Chassis Mount Enclosed Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input NMP1K2 CB, CE, cURus, EAC, TUV 90 ~ 264 VAC, 120 ~ 370 VDC download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9540 1 1020W 5 88.5% 48V 5V 5V 12V 5V - - 4 kV 60601-1; 62368-1 5 A 36 A 36 A 20 A 36 A
CX10S-GCADBD-P-A-DK00000 Advanced Energy CX10S-GCADBD-P-A-DK00000 -
RFQ
ECAD 5332 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GCADBD-P-A-DK00000 EAR99 8504.40.9540 1 1000W 7 93% 24V 24V 24V 5V 48V 12V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 8.3 A 21 A 4.17 A 15 A
CX10S-0CAA0D-P-A-DK00000 Advanced Energy CX10S-0CAA0D-P-A-DK00000 -
RFQ
ECAD 6991 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-0CAA0D-P-A-DK00000 EAR99 8504.40.9540 1 610W 4 93% 24V 5V 5V 48V - - No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 21 A 21 A 4.17 A
MP8-2L-1E-1E-1L-4LD-00 Artesyn Embedded Power MP8-2L-1E-1E-1L-4LD-00 -
RFQ
ECAD 4836 0.00000000 Artesyn Embedded Power MP8 (1000W) Bulk Obsolete -40°C ~ 70°C (With Derating) ITE (Commercial), Medical 10.00" L x 7.00" W x 2.50" H (254.0mm x 177.8mm x 63.5mm) Chassis Mount Enclosed Adjustable Output, PFC, Remote On/Off, Universal Input CB, CE, CSA, UL, VDE 85 ~ 264 VAC, 120 ~ 300 VDC download Not Applicable EAR99 8504.40.7018 1 1000W 6 85% 12V 5V 5V 12V 12V 12V - 30 A 35 A 35 A 17 A 10 A 10 A
CX10S-0DAG0D-P-A-DK00000 Advanced Energy CX10S-0DAG0D-P-A-DK00000 -
RFQ
ECAD 7218 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-0DAG0D-P-A-DK00000 EAR99 8504.40.9540 1 625W 5 93% 48V 5V 24V 24V 48V 48V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 21 A 3 A 3 A 4.17 A
AC6-MZE2H-00 Cosel USA, Inc. AC6-MZE2H-00 727.4900
RFQ
ECAD 2915 0.00000000 Cosel USA, Inc. ACE (650W) Box Active -20°C ~ 70°C ITE (Commercial), Medical 10.98" L x 5.00" W x 2.50" H (278.9mm x 127.0mm x 63.5mm) Chassis Mount Enclosed AC6-MZE2 CE, CSA, cURus, TUV, UL 85 ~ 264 VAC download ROHS3 Compliant Not Applicable EAR99 8504.40.9540 1 5 80% 5V 15V -15V 12V - No 3 kV 60601-1; 60950-1; 62368-1 10 A 2.5 A 3.5 A 13 A 14 A
WX2-4715840-2 Vicor Corporation WX2-4715840-2 -
RFQ
ECAD 3066 0.00000000 Vicor Corporation - Bulk Obsolete - Not Applicable 1102-WX2-4715840-2 OBSOLETE 1
CX10S-BBHHDH-P-A-DK00000 Advanced Energy CX10S-BBHHDH-P-A-DK00000 -
RFQ
ECAD 8655 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-BBHHDH-P-A-DK00000 EAR99 8504.40.9540 1 860W 9 93% 12V 12V 5V 24V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 15 A 15 A 6 A 3 A 6 A 3 A
CX10S-GHB0AH-P-A-DK00000 Advanced Energy CX10S-GHB0AH-P-A-DK00000 -
RFQ
ECAD 7042 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GHB0AH-P-A-DK00000 EAR99 8504.40.9540 1 605W 8 93% 24V 24V 5V 24V 12V 5V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 6 A 3 A 15 A 21 A
  • Daily average RFQ Volume

    2000+

    Daily average RFQ Volume

  • Standard Product Unit

    30,000,000

    Standard Product Unit

  • Worldwide Manufacturers

    2800+

    Worldwide Manufacturers

  • In-stock Warehouse

    15,000 m2

    In-stock Warehouse